Shijiazhuang Fayun Electric Co., Ltd.
Main products:epoxy fiberglass rod,epoxy fiberglass tube,lightning arrestor,insulator
Products
Contact Us
  • Contact Person : Ms. Chan Ivy
  • Company Name : Shijiazhuang Fayun Electric Co., Ltd.
  • Tel : 86-311-83661229
  • Fax : 86-311-83612236
  • Address : Hebei,Shijiazhuang,Shijiazhuang Fayun Electric Co., Ltd. NO. 165 Xinhua West Road, Hebei Province, China
  • Country/Region : China
  • Zip : 050081

Fuses
Organic composite transformer bushing

Organic composite transformer bushing

Organic composite transformer bushing It is an alternative of currently popular ceramic wall bushing which is widely used prese Organic composite transformer bushingAmbient temperature :-40~40Elevation:1000mPollution class:useable for heavily polluted locations of class three or...
composite drop out fuse/cut out fuse

composite drop out fuse/cut out fuse

Fuse cutout parameters: rated voltage:10kv max.operating voltage:12kv Fuse cutout parameters:rated voltage:10kvmax.operating voltage:12kvrated current:100A max.stored drop out current :6.3kAmin. stored drop out current:17kAcreepage distance:> 2.6Cm/kv 1 min.wet power-freqency...
drop out fuse

drop out fuse

Specifications Drop Out Fuse 1)Type:HRW 2)Rated voltage: 13-27KV 3)Leakage Distance: 320mm Drop Out Fusetype   rated voltage(KV)rated current(A)breaking current(KA)impulse voltage BIL(KV)power frequency withstand voltage(KV)leakage...
Insulating drop out fuse

Insulating drop out fuse

High voltage Fuse 1. Voltage :12KV,24KV 2. Fuction: for Transformer protection 3. Standard: IEC The High/Low voltage fuses each have reliable apperance, low in power loss, and high in breaking capacity. They have been widely used in overload and short circuit protection of...
drop-out fuse

drop-out fuse

drop-out fuse parameters: rated voltage:10kv max.operating voltage:12kv drop-out fuse techinical parameters:rated voltage:10kvmax.operating voltage:12kvrated current:100A max.stored drop out current :6.3kAmin. stored drop out current:17kAcreepage distance:> 2.6Cm/kv 1...
Drop Out Fuse/ Cut Out Fuse

Drop Out Fuse/ Cut Out Fuse

drop-out fuse rated voltage:10kv max.operating voltage:12kv drop-out fuse techinical parameters:rated voltage:10kvmax.operating voltage:12kvrated current:100A max.stored drop out current :6.3kAmin. stored drop out current:17kAcreepage distance:> 2.6Cm/kv 1 min.wet...
Drop Out Fuse With Interrupter Device

Drop Out Fuse With Interrupter Device

Epoxy fiberglass rod;Silicon ruber coat Rated voltage:10KV Max.operating voltage:12KV Drop Out Fuse techinical parameters:rated voltage:10KVmax.operating voltage:12KVrated current:100A max.stored drop out current :6.3kAmin. stored drop out current:17kAcreepage distance:>...
Drop Out Fuse Cutout

Drop Out Fuse Cutout

drop-out fuse rated voltage:10kv max.operating voltage:12kv drop-out fuse techinical parameters:rated voltage:10kvmax.operating voltage:12kvrated current:100A max.stored drop out current :6.3kAmin. stored drop out current:17kAcreepage distance:> 2.6Cm/kv 1 min.wet...
drop out fuse cut out

drop out fuse cut out

drop-out fuse parameters: rated voltage:10kv max.operating voltage:12kv drop-out fuse techinical parameters:rated voltage:10kvmax.operating voltage:12kvrated current:100A max.stored drop out current :6.3kAmin. stored drop out current:17kAcreepage distance:> 2.6Cm/kv 1...
Drop Out Fuse Cut

Drop Out Fuse Cut

drop-out fuse parameters: rated voltage:10kv max.operating voltage:12kv drop-out fuse techinical parameters:rated voltage:10kvmax.operating voltage:12kvrated current:100A max.stored drop out current :6.3kAmin. stored drop out current:17kAcreepage distance:> 2.6Cm/kv 1...


Copyright Notice @ 2008-2022 ECVERY Limited and/or its subsidiaries and licensors. All rights reserved.